Karsten Eilertsen
- Head of section
- 22 78 11 50/ 958 34 353
Publications 2015
Dose painting by numbers in a standard treatment planning system using inverted dose prescription maps
Acta Oncol, 54 (9), 1607-13
DOI 10.3109/0284186X.2015.1061690, PubMed 26213311
Favorable outcomes in locally advanced and node positive prostate cancer patients treated with combined pelvic IMRT and androgen deprivation therapy
Radiat Oncol, 10, 232
DOI 10.1186/s13014-015-0540-3, PubMed 26577452
Publications 2012
Imaging the beams eye view in external beam radiotherapy: geometric and dosimetric precision
Department of Physics, Faculty of Mathematics and Natural Sciences, University of Oslo, Oslo
PublikaID 175
A gel tumour phantom for assessment of the accuracy of manual and automatic delineation of gross tumour volume from FDG-PET/CT
Acta Oncol, 52 (3), 636-44
DOI 10.3109/0284186X.2012.718095, PubMed 23075421
Publications 2010
Adaptive radiotherapy based on contrast enhanced cone beam CT imaging
Acta Oncol, 49 (7), 972-7
DOI 10.3109/0284186X.2010.498433, PubMed 20831484
Publications 2008
A simulation of MRI based dose calculations on the basis of radiotherapy planning CT images
Acta Oncol, 47 (7), 1294-302
DOI 10.1080/02841860802256426, PubMed 18663645
Optimal treatment margins for radiotherapy of prostate cancer based on interfraction imaging
Acta Oncol, 47 (7), 1373-81
DOI 10.1080/02841860802244190, PubMed 18654907
The performance of multileaf collimators evaluated by the stripe test
Med Dosim, 34 (3), 202-6
DOI 10.1016/j.meddos.2008.08.005, PubMed 19647629
Fertility issues in patients with prostate cancer
BJU Int, 102 (7), 793-5
DOI 10.1111/j.1464-410X.2008.07739.x, PubMed 18489529
Publications 2007
Consequences of leaf calibration errors on IMRT delivery
Phys Med Biol, 52 (4), 1147-56
DOI 10.1088/0031-9155/52/4/019, PubMed 17264376
Publications 2006
Portal dose image verification: the collapsed cone superposition method applied with different electronic portal imaging devices
Phys Med Biol, 51 (2), 335-49
DOI 10.1088/0031-9155/51/2/010, PubMed 16394342
Data formats, networking, archiving, and telemedicine
In New Technologies in Radiation Oncology (Schlegel W, Bortfeld T, Grosu AL, eds.), Springer, Berlin, Heidelberg, 53-64
PublikaID 174, ISBN 3-540-00321-5
Publications 2003
An algorithm for fast adaptive image binarization with applications in radiotherapy imaging
IEEE Trans Med Imaging, 22 (1), 22-8
DOI 10.1109/TMI.2002.806431, PubMed 12703757
Publications 2000
Implementing DICOM RT in a radiotherapy department
Use of computers in Radiation Therapy, 1, 79-81
PublikaID 177
Publications 1997
Automatic detection of single MLC leaf positions with corrections for penumbral effects and portal imager dose rate characteristics
Phys Med Biol, 42 (2), 313-34
DOI 10.1088/0031-9155/42/2/005, PubMed 9044415
Publications 1994
Methods for fully automated verification of patient set-up in external beam radiotherapy with polygon shaped fields
Phys Med Biol, 39 (6), 993-1012
DOI 10.1088/0031-9155/39/6/006, PubMed 15551575
Publications 1989
A study of the silicon strip detectors and front-end electronics for the small angle tagger in the DELPHI experiment at LEP
K. Eilertsen, Oslo, 104 s.
BIBSYS 961045426